Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Rev. estomatol. Hered ; 29(1): 39-48, ene.-mar. 2019. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1014044

ABSTRACT

Nuevas técnicas nos están permitiendo migrar de la técnica de cera perdida colado por centrifugado convencional (CPCC) a técnicas como la cera perdida colado por inducción (CPCI). Objetivos: Comparar la discrepancia marginal e interna de cofias unitarias de aleación Cobalto-Cromo (Co-Cr) sobre una línea de terminación chamfer, confeccionadas con dos técnicas: CPCC y CPCI, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se fabricaron13 cofias metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La CPCI obtuvo una menor discrepancia marginal e interna en comparación con la CPC pero no se encontró diferencias estadísticamente significativas (p>0,05) entre ambas técnicas. Conclusiones: Aunque en la mayoría de los puntos de evaluación las cofias realizadas mediante la CPCI presento mejores valores de adaptación marginal e interna en comparación con la CPCC estos resultados sólo son valores descriptivos que no fueron concluyentes, ya que en la mayoría de los puntos evaluados no existió diferencia estadísticamente significativa (p>0,05). Observamos que la mayoría de los valores de ambas técnicas se encuentran dentro del rango clínicamente aceptable.


New techniques are allowing us to migrate from the technique of lost wax cast by conventional centrifugation (CPCC) to techniques such as lost wax cast by induction (CPCI). Objectives: To compare the marginal and internal discrepancy of cobalt-chromium (Co-Cr) alloy unit copes on a chamfer termination line, made with two techniques: CPCC and CPCI, determining which technique had better marginal and internal adaptation. Material and Methods: 13 Co-Cr alloy unit copings were fabricated for each technique to be evaluated. Silicon replication was used to evaluate the marginal and internal discrepancies. Each sample was cross-sectioned in the vestibular-palatine and mesio-distal directions, then the cervical, axial and occlusal zones were evaluated with a stereomicroscope. Results: 13 unitary Co-Cr alloy metal cops were manufactured for each technique to be evaluated. The silicone replica was used to evaluate the marginal and internal discrepancies, each sample was cross-sectioned in the vestibulo-palatal direction and in the mesio-distal sense, then with a stereomicroscope, the cervical, axial and occlusal areas were evaluated. Conclusions: The assumptions of normality were evaluated with the Shapiro-Wilk test. The statistical analyzes were Student s t test and U Mann-Whitney test. The CPCI obtained a lower marginal and internal discrepancy compared to the CPC, but no statistically significant differences were found (p >0.05) between both techniques. Conclusions: Although in most of the evaluation points the copings made by the CPCI presented better values of marginal and internal adaptation compared to the CPCC, these results are only descriptive values that were not conclusive, since in most of the evaluated points there was no statistically significant difference (p >0.05). We observed that most of the values of both techniques are within the clinically acceptable range.

2.
Rev. estomatol. Hered ; 28(1): 7-19, ene. 2018. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1014001

ABSTRACT

Nuevas tecnologías nos han permitido migrar de la técnica de cera perdida colada por centrifugado (CPC) a la fabricación aditiva como la fusión selectiva por láser (SLM), proporcionando una mejor adaptación marginal e interna. Objetivos: Comparar la discrepancia marginal e interna en cofias unitarias de Co-Cr sobre 2 líneas de terminación: chamfer y bisel, fabricadas con la CPC y SLM, determinando cual tuvo mejor adaptación marginal e interna. Material y Métodos: Se tuvo 4 grupos de estudio: CPC chamfer (n=13), CPC bisel (n=13), SLM chamfer (n=13) y SLM bisel (n=13). Para evaluar la discrepancia marginal e interna se usó el método de la réplica en silicona, seccionando primero en sentido vestíbulo-palatino (V-P) y segundo en sentido mesio-distal (M-D). Se midió las zonas cervical, axial y oclusal con un estéreo microscopio a 40X. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk, y el análisis estadístico fue con las pruebas t de Student y U Mann-Whitney. La menor discrepancia marginal fue para la SLM chamfer con promedios menores de 24,70±10,29 μm en el corte V-P y de 21,82±5,94 μm en el corte M-D, seguido por la SLM bisel en el corte V-P de 34,12±16,23 μm y en el corte M-D de 35,34±8,91 μm. La CPC bisel en el corte V-P fue de 27,17±21,11 μm y en el corte M-D de 47,91±16,77 μm y para la CPC chamfer en el corte V-P fue de 89,65±58,39 μm y en el corte M-D de 91,72±67,13 μm; la diferencia fue estadísticamente significativa solo para las cofias de SLM chamfer comparándolas con la CPC chamfer. En la discrepancia interna los valores en los 4 grupos no tuvieron diferencias estadísticas. Conclusiones: Según los valores, la mejor adaptación marginal fue para la SLM cham- fer, seguida por la SLM bisel, CPC bisel y la CPC chamfer. En cuanto a la adaptación interna, los valores no fueron concluyentes para decir que técnica fue mejor, pero se logró mejor adaptación en la zona axial que la zona oclusal.


New technologies have allowed us to migrate from the spin-wax casting technique (CPC) to additive manufacturing such as selective laser fusion (SLM), providing a better marginal and internal adaptation. Objectives: To compare the marginal and internal discrepancies in Co-Cr unit metal copings on two termination lines: chamfer and bevel, made with CPC and SLM, determining which technique had the best marginal and internal adaptation. Material and Methods: We had 4 study groups: CPC chamfer (n=13), CPC bevel (n=13), SLM chamfer (n=13), SLM bevel (n=13). To assess marginal and internal discrepancies, the silicone replica technique was used, a first sectioning was performed in the vestibular-palatine (V-P) and a secondin the mesio-distal (M-D) direction. The cervical, axial and occlusal zones were measured in a stereomicroscope at 40X. Results: Normality assumptions were evaluated with the Shapiro-Wilk test. Statistical analyzes were Student's t test and U Mann-Whitney test. The less discrepancy marginal was for the SLM chamfer with mean values less than 24.70±10.29 μm in the V-P cut and 21.82±5.94 μm in the M-D cut, followed by the SLM bevel in the P-V cut of 34.12±16.23 μm and in the cut M-D of 35.34±8.91 μm. The CPC bevel in the V-P cut was 27.17±21.11 μm and in the M-D cut of 47.91±16.77 μm and for the CPC chamfer in the V-P cut was 89.65±58.39 μm and in the M-D cut of 91.72±67.13 μm; the difference was statistically significant only for SLM chamfer copings compared to the CPC chamfer. In the internal discrepancy values, no statistical differences were found among the 4 groups. Conclusions: Accord- ing to the descriptive values the best marginal fit was achieved with the SLM chamfer, followed by the SLM bevel, CPC bevel and CPC chamfer. Regarding internal adaptation, the descriptive values were not conclusive enough to decide which technique was better, but a better adaptation was achieved in the axial zone than in the occlusal zone.

3.
Rev. estomatol. Hered ; 27(2): 88-100, abr. 2017. ilus, graf, tab
Article in Spanish | LILACS | ID: biblio-991176

ABSTRACT

Una buena adaptación marginal disminuye la probabilidad de caries, enfermedad periodontal y fracaso de la restauración. La adaptación interna es el ajuste entre la superficie de la preparación y la superficie interna de la restauración, proporcionando retención. La aleación metálica más usada es la de níquel-cromo (Ni-Cr); sin embargo presenta limitaciones como reacciones alérgicas. La aleación cobalto-cromo (Co-Cr) es una alternativa por tener biocompatibilidad, resistencia mecánica, resistencia a la corrosión y costo aceptable. Las nuevas tecnologías digitalizadas han permitido migrar de la técnica de cera perdida colada por centrifugación (CPC) a la manufactura de fresado o a la fabricación aditiva, como el de fusión selectiva por láser (SLM). Objetivos: Comparar la discrepancia marginal e interna de cofias unitarias de aleación Cobalto-Cromo (Co-Cr) sobre una línea de terminación chamfer, confeccionadas con dos técnicas: CPC y SLM, determinando cual técnica tuvo mejor adaptación marginal e interna. Material y Métodos: Se no hay espacio entre las palabras metálicas unitarias de aleación Co-Cr para cada técnica a evaluar. Se utilizó la réplica de silicona para evaluar las discrepancias marginales e internas, cada muestra fue seccionada en cruz en sentido vestíbulo-palatino y en sentido mesio-distal, luego con un estéreomicroscopio se evaluó la zona cervical, axial y oclusal. Resultados: Se evaluó los supuestos de normalidad con la prueba de Shapiro-Wilk. Los análisis estadísticos fueron la prueba t de Student y U Mann-Whitney. La SLM obtuvo una menor discrepancia marginal en comparación con la CPC encontrándose diferencias estadísticamente significativas (p<0,05) entre ambas técnicas. En cambio, al comparar la discrepancia interna no se encontraron diferencias estadísticas. Conclusiones: La mejor adaptación marginal fue para las cofias metálicas de SLM. En cuanto a la adaptación interna, los valores descriptivos no fueron concluyentes para decidir que técnica fue mejor.


A good marginal adaptation decreases the probability of caries, periodontal disease and failure of there storation. The internal adaptation is the adjustment between the preparation surface and the internal surface of the restoration, providing retention. The most commonly used metal alloy is nickel-chromium (Ni-Cr); how ever it has limitations such as allergic reactions. The cobalt-chromium alloy (Co-Cr) is an alternative to have biocompatibility, mechanical strength, corrosion resistance and acceptable cost. The new digitized technologies havea llowed to migrate from the technique of wax loss cast by centrifugation (CPC) to the manufacture of subtraction or additive manufacturing, such as selective laser melting (SLM). Objectives: To compare the marginal and internal discrepancies of Cobalt-Chromium alloy copings units (Co-Cr) on a chamfer termination line, made with two techniques: CPC and SLM, determining which technique had better marginal and internal adaptation. Material and Methods: 13 Co-Cr alloy unit copings were fabricated for each technique to be evaluated. Silicon replication was used to evaluate the marginal and internal discrepancies. Each sample was cross-sectioned in the vestibular-palatine and mesio-distal directions, then the cervical, axial and occlusal zones were evaluated with a stereomicroscope. Results: The normality assumptions were evaluated with the Shapiro-Wilk test. Statistical analyzes were Student's t test and U Mann-Whitney test. The SLM had a smaller marginal discrepancy compared to CPC, with statistically significant differences (p <0.05) between both techniques. On the other hand, when comparing the internal discrepancy, no statistical differences were found. Conclusions: The best marginal adaptation was for metal fittings of SLM. As for the internal adaptation, the descriptive values were not conclusive to decide which technique was best.

SELECTION OF CITATIONS
SEARCH DETAIL